Vaillant F.28 Fault Code: What It Means and What to Do

Heatmaster London

A white wall-hung boiler in a kitchen cupboard on a cold winter morning, with a small red warning light on its display.

If your Vaillant boiler has stopped and the display shows F.28 (or F.028 on the newest ecoTEC plus models), it means the boiler tried to light but could not detect a flame. After several failed attempts it has shut the gas off and locked itself out for safety.

It is one of the most common Vaillant codes, and it turns up most often in cold weather. Sometimes the cause is outside the boiler and easy to put right, such as gas not reaching the house or a frozen condensate pipe. Other times a part inside the boiler needs attention from a Gas Safe registered engineer.

This guide follows Vaillant's own F28 advice page, its official fault code list and the ecoTEC operating instructions. It covers what the code means, the safe checks you can do yourself, and when to call an engineer.

We repair and service Vaillant boilers across London, from Barnet and North London outwards.

Smell gas? Don't touch any switches. Open windows, turn off the gas at the meter if you can, leave the property and call the National Gas Emergency Service on 0800 111 999.

What F.28 means

Vaillant's official description of F.28 is: "The flame signal was not detected during the ignition phase." In plain terms, the boiler has had an ignition failure on start-up.

When your heating or hot water comes on, the boiler opens the gas valve and sparks the ignition electrode to light the burner. It then checks for a flame signal. If it cannot detect one, it tries again. According to Vaillant's ecoTEC plus operating instructions, after five unsuccessful ignition attempts the boiler switches to fault mode and shows F.28. (Some models differ: the ecoTEC sustain combi manual says three attempts.) Older ecoTEC plus boilers may also show a flame symbol with a cross through it, and on ecoTEC pro boilers a red light comes on.

F.28 is a lock-out. The boiler will not try to light again by itself until it has been reset.

A related code, F.29, means the flame went out while the boiler was already running and it could not relight. Many of the causes and checks below are the same.

What causes F.28

Vaillant groups the causes into three main areas: the gas supply, a frozen or blocked condensate pipe, and ignition problems inside the boiler. Its fault code list and F28 advice page mention:

The first three checks below are things you can do yourself. Everything else is inside the boiler and is a job for a Gas Safe registered engineer.

Safe checks you can do yourself

These are all done from outside the boiler. Do not take the boiler casing off. Vaillant is clear that opening the casing can be dangerous.

  1. Check other gas appliances. Try the gas hob, if you have one. If it lights normally, gas is reaching the house. If it will not light either, the problem is the gas supply, not the boiler. Vaillant suggests getting in touch with your gas supplier.
  2. Check your prepayment meter, if you have one. Make sure there is credit and top up if needed. Vaillant mentions this for both F.28 and F.29.
  3. Check the gas is turned on at the meter. The emergency control valve, usually with a yellow handle, sits next to the gas meter. As EDF explains, the gas is on when the handle is in line with the pipe and off when it is at a right angle to it. Vaillant's manuals also say to check the gas stopcock is open.
  4. In cold weather, check the condensate pipe. Look for a white plastic pipe coming out of the wall near the boiler and running down to a drain. If it has frozen, thaw it as described below. Vaillant says you may also hear bubbling or gurgling from the boiler when this happens.
  5. Reset the boiler, following the method for your model below.

A gas hob burner lit with an even blue flame, showing gas is reaching the house.

Thawing a frozen condensate pipe

Vaillant's advice is to pour warm water along the frozen part of the pipe, using a watering can or jug, until the ice clears and the pipe drains. Do not use boiling water from a kettle. Vaillant warns it can crack or damage the pipe.

A few practical points from the industry's guidance for householders on frozen condensate pipes:

Once the pipe is clear, reset the boiler. If the pipe keeps freezing, Vaillant suggests fitting pipe insulation once it has fully thawed, and keeping the heating on a regular timer in very cold spells rather than leaving it off for days. If it still freezes, it may need rerouting by an installer. Our Worcester Bosch EA 227 guide covers frozen condensate pipes in a little more detail.

How to reset your Vaillant boiler

The reset method varies by model, so check your user manual if you have it:

Give the boiler a few minutes to go through its start-up. If it lights and keeps running, the cause may have been temporary, such as a frozen pipe or a short break in the gas supply. Keep an eye on it.

Don't keep pressing reset

Vaillant's manuals say that if the ignition problem is not fixed after three reset attempts, you should contact a competent person. Our advice is to stop sooner if you can see no obvious cause: if F.28 comes back after a reset, and you have gas at the hob and the condensate pipe is clear, it is time to call an engineer.

Each reset makes the boiler go through its ignition attempts again. Repeated resets will not fix a faulty part, and the code is there for your safety.

What not to do

When to call a Gas Safe engineer

Call a Gas Safe registered engineer if:

An engineer will check the gas pressure at the boiler, the ignition electrode and its lead, the gas valve, the PCB, the condensate trap and the flue, and finish with a combustion check. Make a note of the exact code and your boiler model before you call. It saves time.

A yearly boiler service is the best way to cut the chances of ignition faults, because the engineer checks and cleans the parts that most often cause them.

If you smell gas, or think you have carbon monoxide symptoms (headaches, dizziness, nausea, feeling better when you leave the house), turn off the gas at the meter if you can, open windows, get outside and call the National Gas Emergency Service on 0800 111 999. Every home with a gas appliance should have a working carbon monoxide alarm.

Similar Vaillant codes

Need a hand?

Heatmaster London repairs and services Vaillant boilers across London, including Barnet and North London. If F.28 keeps coming back, or you would rather someone checked it for you, contact us or see our boiler repair and boiler servicing pages. You can also browse our FAQs and the areas we cover. If your boiler will not fire up and there is no code on the display, our boiler not working guide may help.

This is the fifth post in our fault code series. For other brands, see the Worcester Bosch EA 227 fault code (the Worcester equivalent of a no-flame lock-out). For heat pumps and air conditioning, see the Mitsubishi Electric E6 error code and the Daikin U4 error code.