Worcester Bosch EA 227 Fault Code: What It Means and What to Do

Heatmaster London

A white wall-hung boiler in a kitchen cupboard with an amber warning light on its display, beside a frosted window on a cold morning.

If your Worcester Bosch boiler has stopped and the display shows EA 227, or just 227, it means the boiler tried to light its burner but could not detect a flame. For safety, it has shut the gas off and locked itself out until it is reset.

It is one of the most common Worcester Bosch codes, and it often shows up in cold weather. Sometimes the cause is outside the boiler and easy to put right, such as no gas reaching the house or a frozen condensate pipe. Other times something inside the boiler needs attention from a Gas Safe registered engineer.

This guide is based on Worcester Bosch's own installation manuals, user instructions and frozen condensate advice. It covers what the code means, the safe checks you can do yourself, and when to call an engineer.

We repair and service Worcester Bosch boilers across London, from Barnet and North London outwards.

Smell gas? Don't touch any switches. Open windows, turn off the gas at the meter if you can, leave the property and call the National Gas Emergency Service on 0800 111 999.

What EA 227 means

How the code appears depends on your boiler:

They all point to the same problem. When the boiler gets a call for heat or hot water, it opens the gas valve and sparks the ignition electrode. A separate sensor then checks for a flame by detecting a tiny electrical current through it (this is what "ionisation" means). If the boiler cannot detect that flame signal, it stops the gas and shows the code.

Worcester classes 227 as a locking fault. That means the boiler will not restart on its own. It stays off until someone resets it.

A white plastic boiler condensate pipe on an outside brick wall, covered in frost with ice at the bottom on a winter morning.

What causes EA 227

Worcester's own user instructions list three common causes for an EA code that you may be able to spot:

If none of those is the cause, it is usually something inside the boiler. Worcester's installation manuals tell engineers to check, among other things:

All of those are jobs for a Gas Safe registered engineer.

Safe checks you can do yourself

These checks are all done from outside the boiler. Do not take the boiler casing off.

  1. Check you have gas. Try another gas appliance, such as the hob. If that will not light either, the problem is the gas supply rather than the boiler. Worcester's advice is to contact your gas supplier.
  2. Check your prepayment meter, if you have one. Worcester's Greenstar 4000 user instructions specifically suggest checking whether your credit has run out. Top up if needed.
  3. Check the gas valve by the meter. The emergency control valve, usually with a yellow handle, is next to the gas meter. As EDF explains, the gas is on when the handle is in line with the pipe and off when it is at a right angle to the pipe. If it has been knocked to off, turn it back in line with the pipe.
  4. In cold weather, check the condensate pipe. Look for a white or grey plastic pipe coming out of the wall near the boiler and running to a drain. If it has frozen, thaw it as described below.
  5. Check the flue outlet. If it is safe to do so, look from the ground at where the flue leaves the wall or roof. Check nothing is blocking it, such as leaves, a nest, snow, or something stacked or growing in front of it.
  6. Reset the boiler once, using the method for your model below.
  7. Wait a few minutes. Worcester says to wait two or three minutes for the boiler to restart after a reset.

Thawing a frozen condensate pipe

The pipe usually freezes at its most exposed point: the open end, a bend, or where the pipe sags. Only thaw a pipe that is at ground level and easy to reach. Never try to thaw a pipe that is up a ladder or at height.

How to reset your Worcester boiler

The method depends on your model, so check your user manual if you have it:

If the boiler lights and keeps running, the cause may have been temporary, such as a frozen pipe or a supply blip. Keep an eye on it. If the condensate pipe freezes regularly, it is worth getting it rerouted or insulated, which Worcester also recommends.

Don't keep pressing reset

It is tempting to keep resetting, but there is a limit for good reason. If EA 227 comes back after one reset, or after you have thawed the pipe and reset, stop there.

The boiler locks out because it has tried to light and failed. Repeated resets will not fix the cause. On the Greenstar 4000 and 8000, Worcester's manuals say that if five locking faults are reset within 15 minutes, the boiler goes into a "super lock-out" because a potentially safety-critical condition has been detected. At that point it needs an engineer to find and fix the fault.

What not to do

When to call a Gas Safe engineer

Call a Gas Safe registered engineer if:

An engineer will check the gas pressure at the boiler, inspect the ignition and flame sensing electrodes and their leads, clear the condensate trap, check the gas valve, flue and burner, and finish with a combustion check. Make a note of the full code, including the number under the letters, and your boiler model. Worcester's own user guide gives "EA and 227" as an example of what to quote.

A yearly boiler service is the best way to cut the chances of ignition faults, because the engineer checks and cleans the parts that most often cause them.

If you smell gas, or think you have carbon monoxide symptoms (headaches, dizziness, nausea, feeling better when you leave the house), turn off the gas at the meter if you can, open windows, get outside and call the National Gas Emergency Service on 0800 111 999. Every home with a gas appliance should have a working carbon monoxide alarm.

Similar codes

Need a hand?

Heatmaster London repairs and services Worcester Bosch boilers across London, including Barnet and North London. If EA 227 keeps coming back, or you would rather someone checked it for you, contact us or see our boiler repair and boiler servicing pages. You can also browse our FAQs and the areas we cover. If your boiler simply will not fire up and there is no code, our boiler not working guide may help.

This is the third post in our fault code series. If you have a Vaillant boiler, see our guide to the Vaillant F.22 fault code (low water pressure). For air conditioning, see the Daikin U4 error code.

Sources