Daikin U4 Error Code: What It Means and What to Do

Heatmaster London

A white wall-mounted air conditioning unit with a red status light in a bright living room, its remote on a side table.

If your Daikin air conditioner or heat pump has stopped and is showing U4, it means the indoor unit and the outdoor unit have lost contact with each other. Daikin calls it a communication error, and older manuals describe it as a "failure of transmission (between indoor unit and outdoor unit)".

The two halves of a split system are constantly sending signals to each other along a cable. When that conversation stops, the system shuts down to protect itself. Sometimes the cause is as simple as the outdoor unit being switched off or a brief power blip. Other times there is a wiring or circuit board fault that needs an engineer.

This guide is based on Daikin's own operation manuals and the Daikin UK homeowner hub. It covers what U4 means, the safe checks you can do yourself, and when to call an F-Gas certified engineer.

We repair and service air conditioning and heat pumps across London, from Barnet and North London outwards.

What U4 means

U4 appears in Daikin's fault code lists for split air conditioners and for Daikin Altherma heat pumps:

Whatever the system, the meaning is the same: the indoor and outdoor units are not talking to each other, so the system will not heat or cool until the link is restored.

An outdoor air conditioning unit on wall brackets on a brick house, with a rotary isolator switch beside it.

What causes a U4 error

Daikin's UK homeowner hub lists these causes:

Engineers also come across U4 after a power cut, a lightning storm or a surge, after building or decorating work near the cable route, and on new installations where the wiring has been connected the wrong way round.

How to check which code you have

On many Daikin wall units, the code is shown on the remote control. On common Daikin wireless remotes, the steps from the operation manual are:

  1. Hold the TIMER CANCEL button (on some remotes, ON TIMER CANCEL or OFF TIMER CANCEL) for about 5 seconds, until the temperature display flashes.
  2. Press the same button repeatedly until the indoor unit gives a long, continuous beep. The code shown at that moment is your fault code.
  3. A short beep or two quick beeps means that code is not the one. Keep pressing.
  4. To leave the code display, hold the button for 5 seconds again. It also clears by itself after about a minute.

Altherma heat pumps and units with a wired controller show the code on the controller screen instead. Buttons vary by model, so check your own manual if you have it, or use Daikin's error code search. Make a note of the exact code, including any number after it (such as U4-01). It helps the engineer.

Safe checks you can do yourself

These checks only involve switches you are meant to use. Do not take any covers off.

  1. Check the outdoor unit isolator. Most outdoor units have a weatherproof isolator switch on the wall nearby. Make sure it is in the ON position. If someone has switched it off (gardeners and decorators sometimes do), turn it back on.
  2. Check your consumer unit. Look for a tripped breaker or RCD labelled for the air conditioning or heat pump. Some systems have one breaker for the indoor unit and another for the outdoor unit. If one has tripped, switch it back on once. If it trips again straight away, leave it off and call an engineer.
  3. Restart the system. Turn the system off with the remote. Switch it off at the breaker, or at the isolator if that is the only switch, and wait a few minutes. Daikin's manual suggests turning the breaker off and on again if the unit is behaving abnormally after lightning or a power disturbance. Then switch the power back on and try the remote again.
  4. Give it a few minutes. After a power cut, Daikin says the system resumes operation after about 3 minutes, so do not keep pressing buttons straight away.
  5. Have a look, without touching. From a safe distance, check whether the outdoor unit or the visible cable trunking has obvious damage, such as a crushed cover or a cable pulled out after garden or building work.

If U4 clears and stays clear, it may have been a one-off power or signal glitch. Keep an eye on it. If it comes back, book a check rather than restarting the system again and again.

What not to do

When to call an F-Gas engineer

Call an engineer if:

An engineer will check the supply and the isolators, test the communication wiring between the units, look for loose or corroded connections and check the control boards. On multi-split and VRV systems they will also check that every indoor unit is being picked up by the outdoor unit. Daikin's own advice for U4 is to contact your installer if you see this code.

Work on air conditioning and heat pump systems should be carried out by an F-Gas certified engineer. Even though U4 is an electrical fault rather than a refrigerant problem, finding it means working inside both units, which can be close to the refrigerant circuit.

Need a hand?

Heatmaster London is an F-Gas certified company. We repair and service Daikin air conditioning and heat pumps across London, including Barnet and North London. If U4 keeps coming back, or you would rather someone checked it for you, contact us or see our air conditioning repair, air conditioning and heat pump pages. For offices and shops, see commercial. You can also browse our FAQs and the areas we cover.