Draining a central heating system sounds like a big job, but on most homes it is a straightforward few hours of work. You might need to do it to replace or move a radiator, fix a leaking valve, or before a power flush or new boiler.
This guide walks through how to drain the system safely, how to refill it afterwards, and when it makes more sense to book a heating engineer.
When do you need to drain a central heating system?
Common reasons include:
- Replacing, moving or adding a radiator (on a single radiator you can often isolate it instead, see below)
- Fixing a leak on a valve, pipe joint or radiator
- Before a system flush or power flush to clear sludge
- Before a new boiler or a heat pump is fitted
- Adding or topping up a corrosion inhibitor after work on the system
If you only need to take off one radiator, you usually don't need to drain the whole system. Close the valves at both ends of that radiator (count the turns on the lockshield valve so you can reset it), then drain just that radiator into a tray.
What you'll need
- A garden hose long enough to reach an outside drain
- A jubilee clip to hold the hose on the drain-off valve
- An adjustable spanner and a drain valve key (or a flat screwdriver, depending on the valve)
- A radiator bleed key
- Old towels and a bowl or tray
- Corrosion inhibitor for when you refill (check it suits your boiler)
Before you start: know your system
Combi and sealed system boilers are filled from the mains through a filling loop and run under pressure (you'll see a pressure gauge on or under the boiler). There is no tank in the loft.
Open-vent (conventional) systems have a small feed and expansion tank, usually in the loft, which tops the heating water up. You need to stop that tank refilling while you drain.
If you're not sure which you have, look for a pressure gauge on the boiler and a small tank in the loft. Our boiler pressure guide explains the gauge and filling loop in more detail.
How to drain a central heating system, step by step
- Turn the heating off and let it cool. Switch the boiler off at the controls and the electrical spur. Wait until the radiators and pipes are cool to the touch, as the water can be hot enough to scald.
- Stop the system refilling. On an open-vent system, turn off the supply to the feed and expansion tank in the loft (there is usually a small isolation valve on the pipe, or tie the float arm up). On a sealed system, make sure the filling loop valves are closed.
- Find the drain-off valve. It is normally a small brass valve with a square head and a hose outlet, low down on a pipe near a downstairs radiator or by the boiler.
- Attach the hose. Push the hose on, secure it with a jubilee clip and run it to an outside drain. Don't let it lie on a lawn or flower bed, as the water can contain sludge and inhibitor.
- Open the drain-off valve. Turn it slowly with the key or spanner. Water should start to flow.
- Open the bleed valves, top floor first. Opening the radiator bleed valves lets air in so the water can drain freely. Start upstairs and work down.
- Wait for it to finish. Depending on the size of the system, this can take a while. When the flow stops, the system is drained, though a little water will always stay in low pipes and radiators.
How to refill the system
- Close the drain-off valve and remove the hose. Close all the radiator bleed valves.
- Open-vent system: turn the supply to the loft tank back on and let it refill the system. Add inhibitor through the tank, following the product instructions.
- Sealed or combi system: add inhibitor first if the system has a dosing point, then open the filling loop slowly until the gauge reads around 1 to 1.5 bar, and close it again.
- Bleed every radiator. Start downstairs and work up, letting air out of each bleed valve until water appears.
- Check the pressure again. On a sealed system, bleeding will drop the pressure, so top it back up with the filling loop.
- Turn the boiler back on, let the system heat up and check every joint and valve you touched for drips. Bleed again if any radiators are cold at the top.
If some radiators heat up much more slowly than others afterwards, the system may need rebalancing using the lockshield valves.
Tips and common mistakes
- Don't rush the cooling time. Hot system water can scald.
- Protect the floor under any valve you open. A towel and a tray save a lot of mess.
- Old drain-off valves can leak once opened after years of being shut. Have a spare cap or a plan to replace it.
- Always refill with inhibitor. Fresh water without inhibitor speeds up corrosion and sludge.
- Black or very dirty water is a sign of sludge. A system flush may help, and a magnetic filter is worth considering.
When to call a heating engineer
Draining and refilling water is something many homeowners do themselves. Anything to do with the boiler itself, gas pipework or the flue must be done by a Gas Safe registered engineer.
It's also worth calling us if:
- You can't find or open the drain-off valve
- The system won't hold pressure after refilling, or keeps losing it
- Radiators stay cold or the boiler shows a fault code after refilling
- You want a full system flush, new radiators, or a new boiler or heat pump fitted
If your boiler stops working after the job, see our guide on what to check when a boiler isn't working.
Smell gas? Don't touch any switches. Open windows, turn off the gas at the meter if you can, leave the property and call the National Gas Emergency Service on 0800 111 999.