Boiler Pressure: What It Should Be, How to Top It Up, and Why It Keeps Dropping

Heatmaster London

Most modern combi and system boilers in London homes run on a sealed heating system, and that system needs the right amount of water pressure to work. If the pressure drops too low, the boiler will usually lock out and show a fault code. If it climbs too high, the safety valve will start to let water out.

This guide covers what the gauge should read, how to top the pressure up yourself, what to do if it is too high, and when a pressure problem needs an engineer.

What should boiler pressure be?

Look at the pressure gauge on the front or underneath your boiler. Some boilers show it as a dial and some as a number on the display.

Your boiler's manual gives the exact figures for your model, so check it if you still have it.

How to repressurise your boiler

Topping up the pressure is a normal job that most homeowners can do. You only need to do it on the heating side of the system, through a filling loop. Always do it with the boiler switched off and the system cold, so you get a true reading.

Boilers with an external filling loop

An external filling loop is a short braided hose, or a small pipe with a valve, usually found under the boiler between two pipes.

  1. Switch the boiler off and let the system cool.
  2. Check both ends of the filling loop are connected securely.
  3. Open the valve (or both valves, one at a time) slowly. You will hear water running into the system.
  4. Watch the gauge. When it reaches about 1 to 1.5 bar, close the valve or valves fully.
  5. Switch the boiler back on and reset it if it is showing a fault.
  6. If your loop is the detachable kind, disconnect it afterwards and catch any drips in a cloth.

Boilers with a built-in (keyless or key) filling system

Some boilers have the filling system built in underneath. It may use a lever, a blue tap, or a small filling key that slots into the underside of the boiler. The steps differ by model, so follow the manual for yours. The aim is the same: let water in slowly until the gauge reads about 1 to 1.5 bar, then shut it off.

If you are not sure which type you have, or you cannot find the loop, do not force any fittings. Book a visit and an engineer can show you.

What if the pressure is too high?

High pressure is less common than low pressure, but it needs attention. The usual causes are:

If the system has simply been overfilled, you can bring the pressure down by bleeding a radiator. With the heating off and cool, open the bleed valve at the top corner of a radiator with a radiator key, hold a cloth underneath, and let a little water out while you watch the gauge. Close the valve once it is back to around 1 to 1.5 bar.

If the pressure keeps climbing again afterwards, or water is dripping from a small copper pipe on an outside wall (the pressure relief discharge pipe), call an engineer. Recharging or replacing an expansion vessel and checking the relief valve is work for a qualified heating engineer.

Why does my boiler keep losing pressure?

If you top the pressure up and it drops again within days or weeks, water is getting out of the system somewhere. Common reasons include:

A very occasional top-up is not always a worry, but having to top up every week or two, or seeing water anywhere it should not be, points to a fault that should be found and fixed. Keep topping up a leaking system for too long and fresh water keeps entering it, which can speed up corrosion and sludge.

Do not open the boiler casing

Repressurising, bleeding radiators and resetting the boiler are all fine to do yourself. Anything inside the boiler case, and anything on the gas side, must only be done by a Gas Safe registered engineer. If you smell gas, leave the property and call the National Gas Emergency number on 0800 111 999 straight away.

When to call us

Book a visit if:

Heatmaster London is based in Barnet, North London, and repairs and services boilers across London. You can book a boiler repair or service online in a couple of minutes. If your boiler is old and keeps breaking down, see our boiler installation page for replacement options, or read the FAQs.