How to Change a Thermostatic Radiator Valve (TRV)

Heatmaster London

Thermostatic radiator valves, or TRVs, are the numbered valves on the side of most radiators. They let you set a different temperature in each room, which can make a home more comfortable and stop you heating rooms you aren't using.

When one stops working, the radiator might stay cold, stay hot all the time, or ignore the setting. This guide explains how TRVs work, what you can fix yourself, and when to call an engineer.

How a TRV works

A TRV has two parts:

As the room warms, the capsule in the head expands and pushes the pin down, cutting the flow of hot water to the radiator. As it cools, the pin rises and lets water back in. At the other end of the radiator is the lockshield valve, usually under a plain plastic cap, which is set once to balance the system and normally left alone.

Signs your TRV needs attention

If the whole radiator is cold at the top but warm at the bottom, it probably needs bleeding rather than a new valve.

First check: a stuck pin

TRV pins often stick after months of not being used. To check:

  1. Turn the head to its highest setting, then unscrew or unclip the head (most come off by hand, some have a locking ring).
  2. Look at the pin. Press it gently with your finger: it should spring back up.
  3. If it is stuck down, tap it lightly and wiggle it with a pair of pliers until it moves freely. Don't force it or pull it out.
  4. Refit the head and check the radiator warms up.

Changing just the TRV head

If the pin moves freely but the radiator still doesn't respond to the setting, the head may be faulty. Many heads can be swapped without draining anything, because the water stays sealed in the valve body.

  1. Note the brand on the valve body. Heads are not all interchangeable, though adaptors are available for many makes.
  2. Turn the old head to maximum and remove it.
  3. Fit the new head (or adaptor and head), set to maximum, and tighten it by hand.
  4. Set it to the level you want and give it time to respond.

Replacing the whole TRV valve

If the valve body is leaking, seized or the wrong size, the whole valve needs changing. This means opening the system, so take your time.

You'll need a new TRV to suit your pipe size (most homes use 15mm), two adjustable spanners, PTFE tape, a radiator bleed key, towels and a tray.

  1. Turn the heating off and let the radiator cool completely.
  2. Isolate the radiator. Turn the TRV to off (0 or the frost symbol). Remove the lockshield cap and turn the valve clockwise until it closes, counting the turns so you can reset it later.
  3. Drain the radiator. With towels and a tray in place, loosen the nut between the TRV and the radiator, then open the bleed valve to let the water drain out. If the valve won't hold water back, you may need to drain the central heating system down instead.
  4. Remove the old valve. Undo the nut to the radiator and the nut to the pipe, using a second spanner to hold the valve steady so you don't twist the pipe.
  5. Fit the new valve. Wrap PTFE tape around the radiator tail threads (or fit the new tail supplied), fit the valve with a new olive if needed, and tighten both nuts firmly without over-tightening.
  6. Refill and test. Open the lockshield valve by the same number of turns you noted. Open the TRV, bleed the radiator until water appears, and check the joints for drips. On a sealed or combi system, top the boiler pressure back up to around 1 to 1.5 bar.
  7. Turn the heating back on and check the joints again once everything is hot.

Tips

When to call a heating engineer

Swapping a TRV head is a quick DIY job. Replacing the valve body is fine for a confident DIYer, but call us if: